STAGE 3
Stage 3 has a total area of 19,330 SF with mezzanine production support directly accessible from interior stairs. The stage supported by shop/mill on the same floor and additional support spaces above.
Sunnyside’s stages feature state-of-the-art soundproofing, integrated smart grid analog style control systems and ample power distribution. Each stage is fully equipped to support single cam and multi cam television productions, feature films and digital production workflows (XR and VR capable) as well as commercial and marketing campaigns.
See specifications below for details.
- Area: 19,330 SF
- HEIGHT: 37' clear
- Dimensions: 86' x 217'
SPECifications
Expand All +STRUCTURE
- 12″ thick structural concrete slab with 4” isolation slab on top
- Max floor load of 150 lbs/SF, which may be increased to 225 lbs/SF with local reinforcement in below grade garage
- Open-web steel joist roof, with steel joists spaced 5’ on-center
- Roof joists support 30 lbs/SF of suspended production loads
- Clear span
Sound
- Acoustically designed with 10-inch-thick insulated concrete walls; InsulQuilt lined walls, black
- Wall assembly achieves STC Rating of 65+
- Designed to minimum noise criteria rating of NC-25
Power
- Stage has 4000 amps 120/208v – 3 Phase
- 3-phase 5 wire panel providing service via:Eight (8) 400 AMP Cam Locks
Four (4) 200 AMP Cam Locks - 300 amps of distributed power
Air/HVAC
- Rooftop HVAC provides 171 tons cooling / 160 tons heating
- Theatrical purge system
- Vibration isolators and in-line silencers provide near silent operations
- Flex-duct connections
- IDF and MDF rooms generously cooled
Security
- MPAA and Bond compliant Access Control and Security Camera Coverage
- Campus-wide digital access controls, via Aviglon